Air compressor also need to have a good "home"


Release time:

2022/01/10

After the selection and purchase of the air compressor, it cannot be directly started and used, and it can only be put into normal use after installation and debugging. Due to the limitation of the site and other conditions, many air compressors are randomly placed and installed after being purchased, as long as they can be placed. In fact, the placement and installation of the air compressor is also more important, a good placement and installation position can improve the performance and life of the air compressor.

The vibration generated by the air compressor is small, so there is no need for special fixed parts, but the installation of the ground must be flat and the ground should be enough to bear the weight of the compressor to prevent the air compressor from vibrating and causing noise. 2 If the air compressor is installed upstairs, anti-vibration measures must be taken to prevent vibration from being transmitted to the downstairs or resonating to cause harm to the air compressor and the building, and reduce potential safety hazards. 3

Due to the large amount of heat dissipation of the air compressor, both air-cooled and water-cooled models require a good ventilation environment. Too high ambient temperature will cause the compressor to run at high temperature or shut down at over temperature. But it can not be placed in the open air, the sun and rain are not conducive to the use of air compressor, reduce the service life of the machine.

Several ventilation methods are as follows:

A: the air inlet and the air outlet are placed on the wall for the outdoor, which is called free installation;

B: Add exhaust fan;

C: Install the air guide duct to exhaust the air outside the wall;

D: Design of air guide duct equipped with guiding movable plate;

(When necessary, hot air can be guided into the cold machine room to avoid cold junction of its components when the temperature is below zero degrees Celsius)

E: Use the hot air discharged from the machine as warm air.

In the winter of the cold zone, the hot air of the machine can be used to increase the indoor temperature, and the hot air can be discharged outdoors in the summer.

There is a lot of moisture in the humid air. The air compressor should be placed in a dry environment as far as possible to reduce the precipitation of condensed water. In addition, a ball valve is added at the end of the main pipe, and the pipe is inclined by 1~2 ° to facilitate the discharge of condensed water in the pipe.