Reasons for insufficient heat dissipation of air compressor


Release time:

2021/11/12

environmental factors. The air compressor is placed too close to the partition wall or other obstacles; there may be other heat sources near the air compressor.

Corresponding problems can also occur when the radiator is blocked. When there is a lot of dust around the air compressor, it will make the long-term operation and cause the radiator to adhere to a layer of dust or sludge, which will affect the heat dissipation effect. Dirty oil filter may also lead to a certain degree of overheating of the air compressor, because the oil filter of the air compressor will be too dirty to make the oil unable to enter the air compressor according to the normal flow rate, so that the air compressor will heat up rapidly due to the lack of cooling lubricating oil. And the cooling oil level is too low.

If there are corresponding problems due to low oil grade or poor oil quality, it is generally necessary to use the original special air compressor oil or suitable oil. If other low grade or inferior oil is used, the viscosity and specific heat may not meet the requirements and cause the temperature to be too high.